Improvment on meassured variables

New way of meassure

By meassure the best known variables, noise-ratio was imroved.

By measuring the best known variables, applied bias voltage U, electric current I and the known series resistor with resistance Rs. The unknown variables of the sample, potential drop Up, sample resistance Rs, power in sample Pp was calculated with lesser noise.

U_s=IR_s
U_p=U-U_s
R_p=\frac{U}{I}-R_s
P_p=UI-I^2R_s

I have remade the plots with this new approach and it clearly shows much better noise-ratio than before. The calulations before were made by using the noisy-value of the measured potential drop over sample.

20090119-02-overview

By meassure the best known variables, noise-ratio was imroved as shown in this plot.

The sintering image folder at flicker shows you the other plots that were remade.

Leave a Reply